Ultra-compact Digital
Pressure Sensor
AP-C30K (P) Series
Instruction Manual
1. Safety Precautions
WARNING
Do not use this product in safety circuits such as those designed to
protect human workers.
This product does not employ an explosion-proof construction. Do not
use it in the presence of flammable gasses, liquids, or powders.
This is a direct current power supply type sensor. Application of an
alternating current may result in explosion or fire.
Accessories
???
96M1038
3. Pipe Connections
You can select from one of two pressure ports: one on the back of the
sensor that can accommodate a pipe leading directly away from the back
of the sensor, and one on the side of the sensor to accommodate a pipe
leading away from the sensor at a right angle.
1) The pressure port is 1/8 of NPT. Commercially available air pressure
joints and nipples can be used with the port.
When attaching the joint, use a wrench to hold the pressure port in
place as illustrated below.
Hold in place
with wrench
(12mm).
2) Attach the included valve plug to the pressure port not being used.
Hold in place with
wrench (12 mm).
Hexagonal
wrench (5mm)
Valve plug with
hexagonal hole
CAUTION
Do not use a torque in excess of 10 Nm when tightening the joint.
Doing so may damage the joint.
Apply sealing tape when attaching the joint in order to prevent air leaks.
4. Mounting Brackets (option)
Dedicated mounting hardware is available for the sensor, allowing it to be
installed in a range of locations.
Horizontal mounting bracket Wall mounting bracket
(AP-BO1) (AP-BO2)
Faceplate/ceiling mounting bracket Tilted mounting bracket
(AP-BO3) (AP-BO4)
Substitution bracket (AP-BO5)
* Distance between arms is same as the AP-30/40 Series brackets.
1 connector cable (2 m)
1 unit scale label
2. Part Names
SET AP-C33K MODE
MPa
21
Pressure display unit
*Apply the units sticker here.
Pressure display
Mode button
Manual adjustment button
Set button
Wiring
connector
Pressure
port (rear)
Pressure port
(side)
Mounting screws
(M3 x 2)
Operational indicator
Output 1 Output 2
1 2
Approx. ± 90°
1 valve plug with hexagonal hole
1 instruction
manual
Seitenansicht 0
1 2 3 4 5

Inhaltsverzeichnis

Seite 1 - Instruction Manual

1Ultra-compact DigitalPressure SensorAP-C30K (P) SeriesInstruction Manual1. Safety PrecautionsWARNING●Do not use this product in safety circuits such

Seite 2 - 7. Detection Mode Operation

2AP-AO1 Panel mounting bracketSETAP-C33MODEMPaSETAP-C40MODEMPaPanel mounting ringPanel-mounted sampleFront protective coverPanel-mounted sample5. Conn

Seite 3 - 8. Sensor Configuration

3After 4 sec of no key operation.Reference value*Press for 3 sec or more.++Increase the setting.Decrease the setting.Operating modeStandardFocus modeA

Seite 4 - . Active Tuning

49. Explanation of Features Switching the detection range (AP-C30K(P) only)The AP-C30KP allows you to select a detection range. (When using Pa units)

Seite 5 - Display Cause Solution

511. Ambient Pressure CompensationOpen the applied pressure to the surrounding air so that it equals theambient pressure and press the button for 3