Keyence CV-X Series Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
KEYENCE CORPORATION. Vision System Division
‐ 12 ‐ www.keyence.com
3. The command is executed.
4. Check if the values of the devices corresponding to
the PLC Command complete flag and Command
result (B00 and W04 respectively in this example)
have changed.
When the command is successful: CV‐X writes "1" into Command complete
flag, and "0" into Command result.
When the command fails: CVX writes "1" into Command complete flag, and
an error code into Command result.
Command Execution Procedure Example Switch Program Setting No. (PW)
Here is an example of a command execution procedure. This section shows an example of executing the PW (Switch Program
Setting No.) command which uses command parameters. The screens with blue frames show when the "Registration monitor"
function of KV STUDIO is used for confirmation.
Check the PW (Switch Program Setting No.) command operation.
1. Enter "24", the PW command No., in the device
corresponding to the PLC Command number (W0F4 in
this example), and enter the switch target SD drive No.
and program number in the device corresponding to
Command Parameter (W0F6 and W0F8 in this
example).
The figure on the right shows an example of switching
to program number "11" on "SD1".
2. Enter "1" in the device corresponding to the PLC
Command request flag (B060 in this example).
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Kommentare zu diesen Handbüchern

Keine Kommentare