Seitenansicht 61
3-3 Explicit Messaging
3-32
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT2) -
3
Communicating with the GT2 series
Nx10+4
72
Display resolution
R/W 0
0: 0.0001
1: 0.001
2: 0.01
3: 0.1
73
Hysteresis
R/W +000.0030
+000.0000 to +199.9999
74
Simultaneous input setting
*12 R/W 0
0: Individual input
1: Simultaneous input
75
Special output setting
*8 R/W 0
0: Do not use
1: 5-output
2: Limit output
3: Limit output user setting
4: GO for all
5: Limit output for all
76
Limit output switch (HH) position
*8 R/W +000.0000
-199.9999 to +199.9999
77
Limit output switch (LL) position
*8 R/W +000.0000
-199.9999 to +199.9999
78
Select preset data
R/W 0
0: R.V. value
1: P.V. value
79
Preset memory
R/W 0
0: YES
1: NO
7A
Preset point
R/W 0
0: Common to all banks
1: Store separately for each bank
7B
Power-saving function (ECO)
R/W 0
0: OFF
1: HALF
2: ALL
7C
Jam detection function
R/W 0
0: OFF
1: ON
2: USER
7D
Jam detection position
R/W +000.5000
-199.9999 to +199.9999
7E
Batch setting (GT2-100* only)
*14 R/W 0
0: Individual
1: Batch
7F
Analog range setting
*15 R/W 0
0: Default
1: Free range setting
80
Free range setting (Hi)
*15 R/W +012.0000
-199.9999 to +199.9999
81
Free range setting (Lo)
*15 R/W +000.0000
-199.9999 to +199.9999
82 to
83
System reserved
Nx10+5
64
Group-5 entry count
R15
65
R.V. value of main unit (ID: 01) on
which calculation result was based
*3
*6
R
66
R.V. value of expansion unit (ID: 02)
on which calculation result was
based
*3
*6
R
67
R.V. value of expansion unit (ID: 03)
on which calculation result was
based
*3
*6
R
68
R.V. value of expansion unit (ID: 04)
on which calculation result was
based
*3
*6
R
69
R.V. value of expansion unit (ID: 05)
on which calculation result was
based
*3
*6
R
6A
R.V. value of expansion unit (ID: 06)
on which calculation result was
based
*3
*6
R
InstID
(DEC)
AttrID
(HEX)
Name
Description
Attribute
Default
value
Parameter range