Keyence DL-DN1 Bedienungsanleitung Seite 63

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 74
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 62
4-3
4
Specifications
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (FD-S) -
4-2
Data Processing Times
This section describes the length of time taken from detection by a sensor(s) to data
processing by PLC.
Maximum data processing time = (1) + (2) + (3) + (4)
(1) PLC scan time
(2) Network scan time
(3) Data communication time of DL-DN1
(4) Response time of sensor amplifier
(3) Data communication time of DL-DN1
The length of time for the data output or current value to be sent from a sensor
amplifier to the DL-DN1 are summarized below.
Sensor amplifier with calculation function OFF, or sensor amplifier with no calcula-
tion function
For information on (1), (2), and (4), refer to the manual of each unit.
Number of sensor amplifier units
connected
Output/judgment value or current value
1 10.2 ms
2 12.2 ms
3 16.2 ms
4 18.2 ms
CPU unit
DeviceNet
master unit
DL-DN1 Sensor amplifier
KV-DN20
MS
NS
ON
TERM.
(1) (2) (3) (4)
Seitenansicht 62