3-3 Explicit Messaging
3-34
- DeviceNet Compatible Network Unit DL-DN1 User's Manual -
3
Communicating with the IB Series
Nx10+4
78
External input 3 function selection
*18 R/W 0
0: Timing input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not use
79
External input 4 function selection
*18 R/W 4
0: Adjust input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not use
7A
Bank switching method
R/W 0
0: Button
1: External input
7B
Reserved
7C
Save zero-shift state
R/W 0
0: OFF
1: ON
7D
Reserved
7E
Display digit
R/W 0
0: Default
01: 00.0
02: 00.0
03: 00.0
04: 00.1
5: 01
7F
Power save function
R/W 0
0: OFF
1: Half
2: All
080
Reserved
81
Judgment indicator color
R/W 0
0: Green for GO only (Default)
1: Red for GO only
2: All green
3: All red
82
P. V. value display color
R/W 0
0: Green for GO (Default)
1: Red for GO
2: All green
3: All red
83
Reserved
Nx10+5
64
Group-5 entry count
R9
65
Save adjust state
R/W 0
0: OFF
1: ON
66
Adjust level
R/W 20
1 to 30
67
Auto adjust function
R/W 0
0: Disabled
1: Enabled
68
Auto adjust level
R/W 3.00
0.50 to 20.00
69
Check output function
R/W 0
0: Disabled
1: Enabled
6A
Check output light level
R/W 10
1 to 30
6B
Error output mode
R/W 0
0: Normal mode (Default)
1: LX2 compatible mode
6C
Hysteresis for trigger level
R/W 0
0: Default
1: User setting
6D
Hysteresis set value for trigger level
*16 R/W 1.00
0.00 to 999.99
6E to
83
Reserved
InstID
(DEC)
AttrID
(HEX)
Name
Description
Attribute
Default
value
Parameter range