3-6 DP-V1 Service
3-33
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -
Executing Communication
3
84 LOW setting value (BANK 3) *15 DINT R +02.000 -99.999 to +99.999
85 Shift target value (BANK 3) *15 DINT R 00.000 -99.999 to +99.999
86 Sensitivity setting (BANK 3) DINT R 1
0: Low sensitivity mode
1: Standard mode
2: High sensitivity mode
3: User defined
87 User binarize level (Bank 3) DINT R 25 10 to 90
88 User filter value (Bank 3) DINT R 09 03 to 50
89 to 95 Reserved for system
96 Group3 Entry Count DINT R 31
97 Keylock function DINT R/W 0
0: Unlock
1: Key lock
98 Bank function *16 DINT
R 0 0 to 3: Currently active bank
W0
0: Switched to bank 0
1: Switched to bank 1
2: Switched to bank 2
3: Switched to bank 3
99 Timing input request *17 DINT R/W 0
0: Timing input OFF
1: Timing input ON
100 Laser emission stop request *17 DINT R/W 0
0: Laser emission stop input
OFF (laser emitting)
1: Laser emission stop input
ON (laser emission stopped)
101 to
103
Reserved for system
104 Sub display's screen DINT R/W 0
0: R.V. value display screen
1: Analog output screen
2: HIGH setting screen
3: LOW setting screen
4:
Shift target value setting screen
5:
Calculation value display screen
105 System parameter *12 DINT R/W 00 0 to 15
106 Tolerance setting width *18 DINT R/W 00.100 00.000 to 99.999
107 Calibration Function DINT R/W 0
0: Standard
1: User setting
108 Calibration function SET1 DINT R/W 00.000 -99.999 to +99.999
109 Calibration function SET2 DINT R/W +05.000 -99.999 to +99.999
110 to
115
Reserved for system
116
Specified edges interval
measurement mode: Edge
number 1 (BANK 0)
*19 DINT R/W +001 -100 to +100
117
Specified edges interval
measurement mode: Edge
number 2 (BANK 0)
*19 DINT R/W +002 -100 to +100
118
Pin interval judgment mode or
pin diameter judgment mode:
Number of pins (BANK 0)
DINT R/W 02 2 to 14
119
Specified edges interval
measurement mode: Edge
number 1 (BANK 1)
*19 DINT R/W +001 -100 to +100
120
Specified edges interval
measurement mode: Edge
number 2 (BANK 1)
*19 DINT R/W +002 -100 to +100
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value
Seitenansicht 54