3-6 DP-V1 Service
3-28
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT-70A) -
Executing Communication
*1 Functions assigned to the external input request 1 to 3 are as follows:
• External input request 1: PRESET input
• External input request 2: TIMING input
• External input request 3: RESET input
Refer to the GT-70A series user's manual.
*2 If the judgment value is correct, the parameter range is -199.999 to +199.999.
• When the comparator value is over range, "+999.999" is stored.
• When the comparator value is under range, "-999.999" is stored.
• When the comparator value is invalid, "-999.998" is stored.
• When an error occurs, "+1000.000" is stored.
*3 When you use the calculation function and calculation setting is set to other than
standard difference display, a reading error occurs on the expansion unit.
:: : ::
142 Product code 15
Stores the product code of ID
number 15 sensor amplifier.
2byte
WORD
R
143 Reserved for system
144 Revision 1
Stores the revision of ID
number 01 sensor amplifier.
2byte
WORD
R 0101H to FFFFH
:: : :: :
158 Revision 15
Stores the revision of ID
number 15 sensor amplifier.
2byte
WORD
R 0101H to FFFFH
159 Reserved for system
160
Comparator value 0 (ID
Number 1)
Used when reading
comparator value (P.V. value)
of ID number 01.
*2 *3
4byte
DINT
R
-199.9999 to +199.9999:: : ::
174
Comparator value 0 (ID
Number 15)
Used when reading
comparator value (P.V. value)
of ID number 15.
*2 *3
4byte
DINT
R
175 Reserved for system
176
Number of decimal places
(Current value 0, ID
Number 1)
Used when reading the
decimal position of ID number
01 comparator value (P.V.
value).
4byte
DINT
R
:: : ::
190
Number of decimal places
(Current value 0, ID
Number 15)
Used when reading the
decimal position of ID number
15 comparator value (P.V.
value).
4byte
DINT
R
191 to
194
Reserved for system
Index
(DEC)
Function name Description
Data
type
Attribute Value