Parameters of Commands and Responses
This section describes the parameters used with various commands and responses.
Communication commands
There are two types of communication commands: read commands and write commands.
For information on the data, refer to the SK-1000 Series instruction manual supplied with
the sensor amplifiers.
If commands are sent during the period of approx. 3 seconds after the power is turned on,
the communication error (error number: 22) will occur.
ID numbers
This parameter is used with communication commands "SR" and "SW". Specify the ID number of the
target sensor amplifier using two digits (ASCII characters).
(Example) Sensor amplifier with the ID number 00 = 00, sensor amplifier with the ID number 03 = 03
Communication
command
Attribute Description
SR
Read
Reads the data for the specified data number from the sensor amplifier with the
specified ID number.
M0
Reads the comparator value (P.V. value) that DL-RS1A periodically retrieves
from all sensor amplifiers.
MS
Reads the ON/OFF state of the judgment output and alarm output, and the
comparator value (P.V. value) that DL-RS1A periodically retrieves from all
sensor amplifiers.
DRQ input
Reads the ON/OFF state of the judgment output and alarm output, and the
comparator value (P.V. value) that DL-RS1A periodically retrieves from all
sensor amplifiers when a DRQ input is received.
SW
Write
Writes setting data for the specified data number onto the sensor amplifier with
the specified ID number.
AW Writes setting data for the specified data number onto all sensor amplifiers.
Point
Parameters of Commands and Responses
Data numbers
Specify the data number using three digits (ASCII characters).
z Read-only data
The following table lists the types of data that can only be read from the SK-1000 Series sensor
amplifiers.
Writing read-only data results in a communication error (error number: 22).
*1 In the Data format column, "±" indicates that the value can be either "+" or "-" and "*" signifies a
number from "0 to 9".
*2 R: Indicates that the data type can only be read from the sensor amplifiers.
*3 You can read data number "033" to check the error status of the sensor amplifiers. Convert the
five digit number (ASCII characters) read from the sensor amplifiers to a binary number and
check the ON/OFF state of each bit to check the error.
Data
number
Data name
Data
type
*1
Number of
characters
Attribute
*2
Readout range
033 Sensor amplifier error
*3
***** 5 R 0 to 65535
036 Judgment output/Alarm output
*4
** 2 R 0 to 15
037 Judgment value (P.V. value)
*5
±**.***
7R
-99.999 to +99.999
038 Internal measurement value (R.V. value)
*5
7R
039 Peak hold value during hold period
*5
7R
040 Bottom hold value during hold period
*5
7R
043 Bank status * 1 R 0 to 3
044 Timing status * 1 R
0: During sampling
1: Not during sampling
045 Temperature
*6
±***.*
6 R -999.9 to +999.9
046 Humidity
*7
***.*
5 R 0.0 to +100.0
051 Abnormal setting
*8
*1 R
0: Normal setting
1: Abnormal setting
052 External input status ** 2 R 0 to 15
*12
053 EEPROM write result
*10
*1 R
0: Executing
1: Normal termination
2: Execution impossible
054 Zero shift/Zero shift reset result
*9
*1 R
0: Executing
1: Normal termination
2: Execution impossible
055 Reset request result * 1 R
0: Executing
1: Normal termination
2: Execution impossible
056 Current system parameters
*11
** 2 R 0 to 9
193 Product code **** 4 R
Main unit: 4024
Exp. units: 4025
195 Connected sensor head **** 4 R
0000: No connection
0001: Connected
Bit Sensor amplifier error details
0 Overcurrent error
1 EEPROM error
2 Sensor head error
3Unused
4Unused
5Unused
6Unused
7 Head temperature/humidity error
8Unused
Point