Keyence LK-3100 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sensoren Keyence LK-3100 herunter. KEYENCE LK-3100 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Instruction

InstructionManualCCD Laser Displacement SensorLK-3100 Series96M10800

Seite 2 - CONTENTS

10INSTALLATIONAdjust the distance between the sensor head and target by checking thesensor head’s LED operation indicator.OUTPUT CHARACTERISTICS AND L

Seite 3 - 3. Labels location

11This section describes how to mount the sensor head according to thetarget.Measuring distanceLK-011: Approx. 10 mmWhen measuring the thickness of am

Seite 4 - 4. Safety consideration

12This section describes each function to help you make effective use ofthe LK-3100 series.AUTO ZERO functionResets the output voltage to 0 V at the d

Seite 5 - ■ Remote interlock terminal

13Shift adjustment functionAdjusts the analog value zero point using the UP/DOWN keys for shiftadjustment.Holding down the / keys to change the sh

Seite 6 - LK-3100 Series

14Sets an appropriate sensitivity according to the change in target surfacecondition.Set the sensitivity to AUTO for normal use.AUTO:Used to measure v

Seite 7 - Sensor head

15Alarm hold function• Setting DIP switch 1 to the upper position (HOLD)The sensor does not produce the 12 V (approx. 21 mA) analog outputduring alarm

Seite 8 - CONNECTIONS

16Response speed selection functionSet DIP switch 3 to select whether to output every measured value orthe average of 8 measured values (moving averag

Seite 9

17The LK-011 offers two measurement modes to be used according to themeasurement conditions.Normal mode:Used to measure targets other than mirror-surf

Seite 10 - POWER-ON

18USING EACH FUNCTION SAMPLING CYCLE SELECTIONOFFON0MON(V) MON(mA)123AUTOGAINLOWHIGHTIMINGSTABILITYZERO/RESET24V DC INREMOTE GND TIMING ZERO

Seite 11 - Measuring distance

19 Noise interference (The sensor head is case-grounded.)Isolate the sensor cable and extension cable(s) from high-tensionlines or power lines, other

Seite 12 - ZERO function

2SAFETY INFORMATION FOR LK-3100 SERIESThis manual describes how to install the LK-3100 series as well as itsoperating procedures and precautions. Plea

Seite 13 - Span adjustment function

20Timing diagram• Laser emission only starts approximately 3 seconds after the laseremission stop input terminal is connected.• While the timing input

Seite 14 - HIGH LOW

21SPECIFICATIONS1. Linearity was obtained using KEYENCE’s standard target (zirconia block gauge) with the sampling cycle set to 2048 µs.2. Repeatabili

Seite 15 - Key-lock function

22CHARACTERISTICSAngle characteristicsChanges the span of the analog output when a white ceramic target istilted by ±30° (Typical)Normal mode10Analog

Seite 16

23 (1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the date ofshipment. If

Seite 17 - ■ Mirror-surface

242010 10800E 1121-2 96M10800DIMENSIONSUnit: mmSensor headLK-011ø15ø5437.9500.045°79 to 11332 x ø3.2(mounting hole)42.73339.817.7ControllerLK-3101

Seite 18 - ■ Setting the sampling cycle

31. ClassificationSAFETY PRECAUTIONS ON LASER PRODUCTModel LK-011FDA (CDRH) 21 CFR Part 1040.10Class IIIEC/EN 60825-1 Class 2DIN EN 60825-1 Class 22.

Seite 19 - HINTS ON CORRECT USE

44. Safety considerationUse of controls or adjustments or the performance of proceduresother than those specified herein may result in hazardous radia

Seite 20 - INPUT CHARACTERISTICS

5SAFETY PRECAUTIONS ON LASER PRODUCTKey-operatedlaser switchLK-011LASER ON0.95mW670nmLASER RADIATIONDO NOT STARE INTO BEAMMaximum outputEmitted

Seite 21 - SPECIFICATIONS

6The LK-3100 series package includes the following parts and equipment.Ensure that these items are included in your package before using theunit.Contr

Seite 22 - Angle characteristics

7ControllerPART NAMESSensor head0MON(V)MON(mA)123AUTOGAINLOWHIGHTIMINGSTABULITYBRIGHTDARKLASER ONZERO/RESETSHIFTRESETSPAN24V DC INREMOTEGNDTIMINGZEROG

Seite 23 - WARRANTIES AND DISCLAIMERS

8CONNECTIONSThis section describes each terminal.Analog output 0 VAnalog voltage output (V)Analog current output (mA)0+–24 VDCPower supply 24 VDCREMOT

Seite 24 - Extension cable (option)

9INPUT/OUTPUT CIRCUIT INSTALLATION24 V3 KΩ470 ΩINGND6.8 ΩGNDNPN outputControllerExtension cable (Options)LK-C2 (2m)LK-C5 (5 m)LK-C10 (10 m)Sensor head