1 FS-N Series
3
- Sensor Amplifier Network Manual -
For the FS-N series, the data parameters that can be communicated via a network
unit are specified as follows:
Parameter Available settings
Current Value 0 to 9999
Setting Value 0 to 9999
Current Value Prop-
erty
Over Range (Not used with FS-N)
Under Range (Not used with FS-N)
Invalid (Not used with FS-N)
Sensor Error
0: No Error
1: Overcurrent Error
2: Not used
3: EEPROM Error
4: Not used
5: Not used
6: DATUM Correction Error
7: APC Error
Sensor Warning
0: No Warning
1: Limit Output ON
Key Lock
0: Unlock
1: Key Lock
2: PIN Code Lock
3: Communication Lock
Product Code
FS-N10: 2000
FS-N12: 2000
FS-N14: 2001
Head Code (Not used with FS-N)
L-on/D-on (N.O./N.C.)
0: OUT1: L-on / OUT2: L-on
1: OUT1: D-on / OUT2: L-on
2: OUT1: L-on / OUT2: D-on
3: OUT1: D-on / OUT2: D-on