2-7
2
2 Screen Functions and Operation
Setting 2
(1) Median
Sets the number of sampling points to use for the median filter.
(2) LASER CTRL group
Sets the LASER control group.
(3) Range
Sets the range.
(4) No. of alarm processing
Sets the number of cycles to hold the most recent valid measurement (Setting range: 0 to
9999).
(5) No. of alarm recovery
Sets the number of cycles to measure before automatically recovering from the alarm state
(Setting range: 0 to 9999).
(6) Alarm level
Sets the alarm sensitivity level from between low (0) to high (9) (default setting: 4).
Low (0): Weakens alarm detection sensitivity
High (9): Increases alarm detection sensitivity
Process count Operation
0 Handles alarm immediately
1 to 9998 Holds most recent valid measurement
9999 Alarms off
(3)
(1)
(2)
(4)
(5)
(6)