Example of connections
When connecting an NPN output PLC to the controller input
When connecting a PNP output PLC to the controller input
PLC (NPN output) Input circuit on controller
PLC (PNP output)
Input circuit on controller
Output circuit diagram (NPN output type)
Output circuit diagram (PNP output type, controllers with a "P" at the end of the part number)
Maximum applied voltage: 30 V
Maximum sink current: 50 mA
Leakage current: 0.1 mA or less
Residual voltage:
1.4 V or less (50 mA)
1.0 V or less (20 mA)
Maximum applied voltage: 30 V
Maximum sink current: 50 mA
Leakage current: 0.1 mA or less
Residual voltage:
1.4 V or less (50 mA)
1.0 V or less (20 mA)
(No. 18, 19, 20)
(No. 17)