3. Controlling the Controller (PLC-Link) [MELSEC FX Series]
1
Checking the Global Settings of the CV-X Series
On the "Global" menu, select [Communications & I/O] > [PLC-Link] to open the global "PLC-Link" settings
screen.
2
Check the setting items necessary for controller control.
Select the Command Execute Event.
Select Polling for Command Execute Event.
Check the data memory to use for the following three items.
Command Address
Command Complete Address (bit)
Command Result Address
3
Select "OK" to close the global "PLC-Link" settings screen.
The data memory address to use can be changed.
Be careful not to specify an address of a data memory being used for another program of PLC.