Keyence PX-10 Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 10
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
10
Copyright (c) 2007 KEYENCE CORPORATION. All rights reserved.
1591E 1062-3a 96M1591 Printed in Japan
Specifications
Sensor head
* Note that when using the sensor underwater, the detection distance becomes
extremely short.
Amplifier
* 1
When the sensor head cable is 3 m or longer, use a power supply voltage of 24 V DC.
* 2 When using several units in close proximity.
2 to 4 units : 55°C
5+ units : 45°C
Hints On Correct Use
Do not wire the amplifier line along with power lines or high-tension lines,
otherwise the sensor may malfunction or receive damage due to noise.
When using a commercially available switching regulator, ground the frame
ground terminal and ground terminal.
Do not use the PX series outdoors, or in a place where extraneous light can enter
the light receiving surface directly.
Due to the individual dispersion of characteristics and the difference in sensor
head model, the maximum sensing distance or displayed value of all the units are
not the same.
Changing the cable layout can change the light intensity slightly. Reset the
sensitivity when changing the layout.
Even when using the interference prevention function, devices installed and
connected to the sensor may have a slight effect on detection. In these cases,
fine-adjust the sensitivity (raise the value).
Infrared light used for communicating with the amplifier unit emits from the back
of the amplifier unit. Make sure that the receiving head is not used too close to the
amplifier unit.
Do not use the sensor while it is submerged in oil.
Performance may be lowered depending on the type of oil.
Precautions on UL Certificate
The PX series complies with the following UL and CSA standards. The PX series
has obtained UL and C-UL certificate.
Applicable standard UL508 Industrial Control Equipment
CAN/CSA C22.2 No.14-M05 Industrial Control Equipment
UL File No. E301717
UL category: NRKH, NRKH7
Enclosure Type 1 (according to UL50)
Precautions
The PX series must be supplied from the power source defined as Class 2
according to NFPA70 (NEC: National Electrical Code).
The UL certificate for the PX series is for the sensor head unit and the amplifier
unit used in combination. The PX-H series (the sensor head unit) must be used
together with the PX-10 series (amplifier unit) exclusively.
Warranties and Disclaimers
KEYENCE, at its sole option, will refund, repair or replace at no charge any
defective Products within 1 year from the date of shipment. Unless stated
otherwise herein, the Products should not be used internally in humans, for human
transportation, as safety devices or fail-safe systems. EXCEPT FOR THE
FOREGOING, ALL EXPRESS, IMPLIED AND STATUTORY WARRANTIES,
INCLUDING WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE AND NONINFRINGEMENT OF PROPRIETARY RIGHTS,
ARE EXPRESSLY DISCLAIMED. KEYENCE SHALL NOT BE LIABLE FOR ANY
DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES,
EVEN IF DAMAGES RESULT FROM THE USE OF THE PRODUCTS IN
ACCORDANCE WITH ANY SUGGESTIONS OR INFORMATION PROVIDED BY
KEYENCE. In some jurisdictions, some of the foregoing warranty disclaimers or
damage limitations may not apply.
E 1101-3
Ty pe
Thrubeam Reflective
M8 straight M8 nut M12 straight M12 straight
Cable Normal Spiral Normal Normal Spiral Normal Spiral
Model PX-H71 PX-H71G
PX-H71TZ
PX-H72 PX-H72G PX-H61 PX-H61G
Enclosure rating IEC: IP68, JEM: IP68g, NEMA: 4X,6P,13, DIN: IP69K
Light source
4 element red LED
(Wavelength: 635 nm)
Infrared LED
(
Wavelength: 870 nm
)
4 element red LED
(
Wavelength: 635 nm
)
Detection
distance
TURBO 4 m 10 m 400 mm
SUPER 6 m 15 m 600 mm
ULTRA 12 m 30 m 1200 mm
MEGA 20 m 40 m 2000 mm
Standard
detecting object
φ 4 mm opaque object
φ 7.5 mm opaque
object
Spot size
Detection distance
15 mm at 100 mm
65 mm at 500 mm
Environ-
ment
resistance
Operating
ambient
light
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.
Operating
ambient
temperature
-10 to +55°C (No freezing)
Operating
ambient
humidity
35 to 85% RH (No condensation)
Vibration
resistance
10 to 55 Hz, Compound amplitude 1.5 mm, 2 hours for each of XYZ axes
Material
Housing SUS303 (plastic portions: PMP, POM)
Lens Glass
Cable PVC
Connector
portion
PBT, NBR, POM, SUS304
Cable length 2 m
Accessory
The connector is
connected to the
cable.
M8 nut x4
Metal
washer x2
M8 nut x4
Metal
washer x2
M8 nut x2
Metal
washer x2
M12 nut x4
Metal
washer x2
M12 nut x4
Metal
washer x2
M13 nut x2
Metal
washer x1
M13 nut x2
Metal
washer x1
Weight
Approx.
80 g
Approx.
250 g
Approx.
88 g
Approx.
90 g
Approx.
260 g
Approx.
80 g
Approx.
220 g
Type Cable type Connector type
Model
NPN output PX-10 PX-10C
PNP output PX-10P PX-10CP
Response time
500 µs (TURBO)/1 ms (SUPER)/
4 ms (ULTRA)/16 ms (MEGA)
Control
output
NPN output
NPN open collector, 40 V, 100 mA max. per output
2 outputs for total 100 mA max., residual voltage 1 V max.
PNP output
PNP open collector, 30 V, 100 mA max. per output
2 outputs for total 100 mA max., residual voltage 1 V max.
External input Input time, ON: 2 ms, OFF: 20 ms max.
Number of units required to
prevent interference
4 (when all are in power mode)
Power voltage
*1
12-24 VDC, Ripple (P-P): 10% max, Class2
Current consumption
Normal: 50 mA max. at 24 V, 55 mA max. at 12 V
Power saving: 40 mA max. at 24 V, 45 mA max at 12 V
Environment
al resistance
Enclosure
rating
IEC: IP67 JEM: IP67 NEMA: 4X
Operating
ambient
temperature
*2
-10 to +55°C (No freezing)
Operating
ambient
humidity
35 to 85% RH (No condensation)
Vibration
resistance
10 to 55 Hz Compound amplitude 1.5 mm,
2 hours for each of XYZ axes
Case material
Main unit: PBT, display portion: PSU, display cover and connector
cover: SUS304, heat sink: SUS304, gasket: NBR
Accessory Instruction Manual
Weight Approx. 100g Approx. 50 g
Seitenansicht 9
1 2 3 4 5 6 7 8 9 10

Kommentare zu diesen Handbüchern

Keine Kommentare