3
After 4 sec
of no key
operation.
Reference value*
Press for 3 sec or more.
+
+
Increase the
setting.
Decrease the
setting.
Operating mode
Standard
Focus mode
AP-
C30K(P)
only
AP-C31K(P)/
C33K(P)
When
operating
mode is
Two-point tuning
Active tuning
Display color (7-segment)
ON: Red, OFF: Green
ON: Green, OFF: Red
Normally red
Normally green
Within set value: Green
Outside set value: Red
Detection range (AP-C30K(P) only)
Units
Positive pressure range
Compound pressure range
Negative pressure range
Focus center pressure
Toggling the
display
Manual configuration
Settings are
manually
configured. The
display changes
for each mode.
* Toggling the
display of
settings (see the
diagram below).
* Manual
configuration
only during F-3/A-
2 mode operation.
Current value
Peak hold
Bottom hold
* The reference value is
the pressure value when
zero shift input is
received and is replaced
only when zero shift
input is selected.
Mode
configuration
Current value
Reference value
Hold value
Detection mode
General-purpose mode
Variable hysteresis mode
Window mode
Application mode 1
Application mode 2
Zero shift input
Analog output
N.O./N.C.
N.O.
N.O.
N.C.
N.C.
N.O.
N.C.
N.C.
N.O.
Control
output 1
Control
output 2
2.5 msec
5 msec
100 msec
500 msec
Analog/zero shift
Chatter prevention
Sets response time.
• N.O. = normal open.
• N.C. = normal close.
Standard
Eco mode
Power-save
* See the Focus Mode section of
Part 9 for the center pressures
that can be selected.
* F-1 and F-2 mode only
Values that fall between the P1
and P2 settings will be displayed
in green, while values outside
that range will be displayed in
red.
*
When
A-1/A-2 is
selected
during
fixed mode
operation
()
Pa
kgf/cm
2
(AP-C30/C33 only)
mmHg (AP-C30/C31only)
inHg (AP-C30/C31only)
psi
bar
8. Sensor Configuration
Toggling the display of settings
General-purpose mode/F1
Variable hysteresis mode/F-2
Window mode/F-3
Application mode 1/A-1
Application mode 2/A-2
Two-point tuning (F-1/F-2)
The sensor is made to detect the pressures when the target object is
present and then absent for confirmation of target suction pick-up, and
the intermediate value is used.
Control output 1 configuration: When P1 (H1) is selected on the settings
display.
Control output 2 configuration: When P2 (H2) is selected on the settings
display.
Flashes
for 3 sec.
Setting
Target object
present
Target object
absent
Active tuning (A-1)
See Section 10.
Note:Press and hold the MODE button ( ) for at least 3 seconds to return to the current
value/reference value/hold value display from each of the mode setting screens.
Press the left side on the manual adjustment button ( ) while holding down the
mode button ( ) to return to the previous display.
The current value will be displayed based on the ambient pressure conditions prevalent
at that time without regard to zero shift input when the P2 setting display is selected for
A-1 mode or when the Hi and Lo setting displays are selected for A-2 mode.
The sensor must be configured manually when operating in the F-3/A-2 modes. The
SET button ( ) will not function.