3-1 CC-Link Communication and Operating Modes
3-3
3
Communicating with the SK-1000 Series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
Select an operating mode of the DL-CL1 to suit the functions of the sensor amplifiers
to be used.
The specific CC-Link device configuration and the data that can be communicated
using cyclic transfer vary w ith each operating mode of the DL-CL1. An appropriate
operating mode should be determined by considering the number of link points the
data that can be communicated.
"Configuring the Data Link" (page 2-10)
Yes: Available with sensor amplifiers of ID 01 to 08. No: Not available.
*1 For details of the functions assigned for motions commands and setting/status read/write,
see "Device Maps" (page 3-4) and "Command Parameter List" (page 3-26).
*2 In remote register RWw, specify the ID number of the sensor amplifier from which to read.
*3 To use this communication method, create a program that controls commands by handshaking
between a remote input/output and remote register.
Selecting an Operating Mode of the DL-CL1
Method of
communication
with the master
station
Available function
of sensor
amplifier
*1
Operating mode of DL-CL1
Reference
page for
communication
method
Small-
memory
mode 1
Small-
memory
mode 2
Monitor
mode 1
Monitor
mode 2
Full
mode 1
Full
mode 2
1-station,
1x
2-station,
1x
4-station,
1x
1-station,
8x
4-station,
2x
2-station,
8x
page 3-4 page 3-12
Remote input RX Read out-
puts 1 - 5
HI Yes Yes Yes Yes Yes Yes 3-4
LO No Yes Yes Yes Yes Yes
GO No Yes Yes Yes Yes Yes
Alarm
output
No No Yes Yes Yes Yes
Not
used
– – – – – –
Remote register RWr Read judgment
value (P.V. value)
No No
Yes
*2
Yes Yes Yes
3-7
Remote output RY External
inputs 1-5
External
input 1
Yes Yes Yes Yes Yes Yes
3-14
External
input 2
No Yes Yes Yes Yes Yes
External
input 3
No Yes Yes Yes Yes Yes
External
input 4
No No Yes Yes Yes Yes
Not
used
– – – – – –
Remote register
RWw
Change BANK number
No No Yes Yes Yes Yes 3-17
Rewrite setting
value
No No No No Yes Yes
3-17
Handshake control
program
*3
(Command commu-
nication)
Motion command No No Yes Yes Yes Yes 3-22
Read output
No No Yes Yes Yes Yes
3-18
Read judgment
value (P.V. value)
Read external input
status
Read BANK number
Read setting/status
Write setting/status
Kommentare zu diesen Handbüchern