3-3 Adjusting Sensitivity
3
Basic Operation
3-9
- Digital Fiber Sensor FS-N10 Series User's Manual -
This function automatically judges 2 states (workpiece presence/absence, etc.), and
calibrates the current value to "100.0" and ".0".
This is useful when the detector is moving at high speed, etc.
* Not available for the FS-N10 Series shipped before March 10, 2011.
Enabling the full auto preset function
1
When the PST indicator is OFF, con-
tinue pressing the [PRESET] button
until "Auto" flashes while the work-
piece passes through.
2
After the workpiece has completely
passed through, release the [PRESET]
button.
Calibration is complete after the setting
value flashes momentarily, and then
stops (lights up).
The PST indicator lights in green, and the
setting value is set to "50.0".
When the received light intensity is in a saturated condition (more
than the amount specified in "Display Gain" (page 4-32).), full-auto-
matic preset function is disabled. ("---- ----" will appear during
step 2.)
"Light emission/Received light intensity adjustment (Saturation
Canceling)" (page 3-18)
Full Auto Preset Function
Workpiece
Setting
value
MAX
MIN
Time
Received
light intensity
The area near the maximum value
of the received light intensity while
the [PRESET] button is pressed is
set as "100.0", and the area near
the minimum value is set as ".0".
1
2
"100.0"
"50.0"
".0"
Point