GT2-100-M-E
Specifications
Sensor head
GT2-P***/PA*** cannot be connected to amplifier units purchased before April 15th 2014.
Pencil type (GT2-PA12K/PA12 are air cylinder types)
*1 When the surrounding temperature is
20°C.
*2 This is a typical value at the center of the measuring range. The measuring force varies depending on the mounted condition of the dust boot.
For GT2-PA12K/PA12, this is a representative value when using 0.25 MPa. The measuring force varies depending on the air pressure used. See table 1 for more details.
There is no dust boot for GT2-PA12K/PA12.
*3 When using an M8 oil resistant cable (GT2-CHP2M/5M/10M) as the sensor head cable.
*4 The contact is a separately sold option.
*5 Including the relay connector.
Note: Cannot be used with amplifier units purchased before April 15th, 2014.
Box type
*1 When the surrounding temperature is
20°C.
*2 This is a typical value at the center of the measuring range. The measuring force varies depending on the mounted condition of the dust boot.
*3 The contact is a separately sold option.
Air cylinder type
*1 When the surrounding temperature is
20°C.
*2 This is a typical value at the center of the measuring range. The measuring force varies depending on the mounted condition of the dust boot.
*3 Connect an air tube to the exhaust valve so that no foreign materials enter from the valve.
*4 When using mounting bracket D (OP-84327) with GT2-A32/A50, vibration is 0.75 mm.
*5 The contact is a separately sold option.
Model
GT2-P12K GT2-P12KF GT2-P12KL GT2-P12 GT2-P12F GT2-P12L GT2-PA12K GT2-PA12
Detection system Scale shot system II Absolute type (without tracking error)
Measuring range
12 mm
Resolution
0.1 µm 0.5 µm 0.1 µm
0.5 µm
Indication accuracy
*1
1 µm (P-P) 2 µm (P-P) 1 µm (P-P)
2 µm (P-P)
Measuring force
*2
When installed facing down
1.0 N 0.2 N 1.0 N 0.2 N 1.2 N
When installed sideways
0.95 N 0.15 N 0.95 N 0.15 N 1.15 N
When installed facing up
0.9 N 0.1 N 0.9 N 0.1 N 1.1 N
Sampling interval
4 ms
Mechanical response
*1
10 Hz 4 Hz 10 Hz 4 Hz -
Pressure range - 0.24 to 0.26 MPa
Max. pressure -0.5 MPa
Fluid to use - Clean dry air
Operation indicator 2-color LED (red, green)
Environmental
resistance
Enclosure rating
IP67G (JIS)
*
3
IP67 (IEC)
NEMA Type 13
*
3
-
IP67G (JIS)
*
3
IP67 (IEC)
NEMA Type 13
*
3
-
IP67(IEC)
Surrounding air temperature -10 to +55°C (No freezing) 0 to +55°C (No freezing)
Relative humidity 35 to 85% RH (No condensation)
Vibration resistance 10 to 55 Hz, Compound amplitude 1.5 mm, 2 hours each in X, Y, and Z axis
Shock resistance 1000 m/s
2
(IEC60068-2-27)
Material
Main unit
Main unit cover: SUS303, Spindle for GT2-PA12K/PA12: SUS430 (Fluorine-based coating), Indicator: PET, Sensor head - Connection cable: PUR, Connector: PBT,
Dust seal (GT2-PA12K/PA12 only): SUS303/SU304/aluminium (alumite treated)/special polyester fiber
Dust boot
NBR - NBR -
Contact point
*4
SUS304, tungsten carbide SUS304, SUS440C
SUS304,
tungsten carbide
SUS304,
SUS440C
Head cable Sold separately (connected to relay connector)
Weight (excluding cable)
*5
Approx. 35 g Approx. 45 g Approx. 35 g Approx. 45 g Approx. 35 g
Model
GT2-H12K GT2-H12KL GT2-H12KF GT2-H12KLF GT2-H12 GT2-H12L GT2-H12F GT2-H12LF GT2-H32 GT2-H32L GT2-H50
Detection system Scale shot system II Absolute type (without tracking error)
Measuring range 12 mm 32 mm 50 mm
Resolution 0.1 µm 0.5 µm
Indication accuracy
*1
1 µm (P-P) 2 µm (P-P) 3 µm (P-P)
3.5 µm (P-P)
Measuring force
*2
When installed facing down 1.0 N 0.4 N 1.0 N 0.4 N 1.0 N 0.4 N 1.0 N 0.4 N 2.1 N 1.2 N 3.2 N
When installed sideways 0.9 N 0.3 N 0.9 N 0.3 N 0.9 N 0.3 N 0.9 N 0.3 N 1.8 N 0.9 N 2.8 N
When installed facing up 0.8 N 0.2 N 0.8 N 0.2 N 0.8 N 0.2 N 0.8 N 0.2 N 1.5 N 0.6 N 2.4 N
Sampling interval 1 ms
Mechanical response
*1
10 Hz 4 Hz 10 Hz 4 Hz 10 Hz 4 Hz 10 Hz 4 Hz 6 Hz 5 Hz 7 Hz
Operation indicator 2-color LED (red, green)
Environmental
resistance
Enclosure rating IP67 - IP67 - IP67 - IP67 - IP67 - IP67
Surrounding air temperature -10 to +55°C (No freezing)
Relative humidity 35 to 85% RH (No condensation)
Vibration resistance 10 to 55 Hz, Compound amplitude 1.5 mm, 2 hours each in X, Y, and Z axis
Shock resistance
1000 m/s
2
(IEC60068-2-27)
Material
Main unit Main unit cover: zinc die-cast, Indicator: polyarylate (PAR)
Dust boot NBR - NBR - NBR - NBR - NBR - NBR
Contact point
*3
SUS304, tungsten carbide SUS304, SUS440C
Cable Sold separately (connected to M8 connector)
Weight (excluding cable)
Approx. 95 g Approx. 95 g Approx. 100 g Approx. 100 g Approx. 95 g Approx. 95 g Approx. 100 g Approx. 100 g Approx. 270 g Approx. 320 g
Model GT2-A12K GT2-A12KL GT2-A12 GT2-A12L GT2-A32 GT2-A50
Detection system Scale shot system II Absolute type (without tracking error)
Measuring range 12 mm 32 mm 50 mm
Resolution 0.1 µm 0.5 µm
Indication accuracy
*1
1 µm (P-P) 2 µm (P-P) 3 µm (P-P) 3.5 µm (P-P)
Measuring force
*2
When installed facing down 1.2 N 0.4 N 1.2 N 0.4 N 2.1 N 3.2 N
When installed sideways 1.1 N 0.3 N 1.1 N 0.3 N 1.8 N 2.8 N
When installed facing up 1.0 N 0.2 N 1.0 N 0.2 N 1.5 N 2.4 N
Sampling interval 1 ms
Operation indicator 2-color LED (red, green)
Pressure range 0.25 to 0.5 MPa
Max. pressure 1.0 MPa
Fluid to use Dry air
Environmental
resistance
Enclosure rating
IP67
*3
-
IP67
*3
-
IP67
*3
Surrounding air temperature 0 to +55°C (No freezing)
Relative humidity 35 to 85% RH (No condensation)
Vibration
*4
10 to 55 Hz, Compound amplitude 1.5 mm, 2 hours each in X, Y, and Z axis
Shock resistance
1000 m/s
2
(IEC60068-2-27)
-
Material
Main unit
Main unit cover: zinc die-cast, Cylinder: aluminum alloy, Air coupling socket (resin part): polyacetal, Air coupling socket (metal part): nickel plated brass, Indicator: polyarylate (PAR)
Dust boot FKM - NBR - NBR
Contact point
*5
SUS304, tungsten carbide
SUS304, SUS440C SUS304, SUS440C
Sensor head cable Sold separately (connected to M8 connector)
Weight (excluding sensor head cable) Approx. 145 g Approx. 340 g Approx. 405 g
0123456789101112
Measuring force (N)
Spindle retractedSpindle extended
Table 1. Relationship between spindle position and measuring force grouped according to used air pressure.
(When installing side mounting, the measuring force is -0.05 N. When installing upward mounting, the measuring force is -0.1 N.)
Spindle position (mm)
Applied pressure (MPa)
1.7
1.2
0.26 MPa
0.25 MPa
0.24 MPa
0.7