Keyence LS-Navigator Bedienungsanleitung Seite 47

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 68
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 46
5
5-15
LS-Navigator-M-NO5-E
5-7 Setting RS-232C Communication Conditions
7
Click on the [Next] button.
A message appears on the [Setting Wizard],
instructing the user to set the same values as
shown for the communication settings on the
controller.
The communication settings for the LS-7600/7500
series and the LS-7000 series are different in the
following manner.
For the LS-7600/7500 series
(1) Set the same value for [Baud rate] as displayed on the controller.
Select among 1200, 2400, 4800, 9600, 19200, 36400, 57600, or 115200 from the pull-down menu.
(2) Set the same value for [Parity] as displayed on the controller.
Select among NONE, ODD, or EVEN from the pull-down menu.
(3) Set the same value for [Stop bit] as displayed on the controller.
Select between 1 and 2 from the pull-down menu.
(4) Set the same value for [Data length] as displayed on the controller.
Select between 7 and 8 from the pull-down menu.
(1)
6
(2)
(3)
(4)