Chapter 3 Simulator
2-113
1
3
3.4.3 Monitor all window
• To look at the hidden (undisplayed) portion, use the scroll bar or the [PageUp]
and [PageDown] keys.
• The cursor can be moved using the [LEFT] [RIGHT] [UP][DOWN] keys.
• While the simulator is running, the current values are changed accordingly.
Current value display format
B: Bit
O: Byte
D: Binary without sign
d: Binary with sign
H: Hexadecimal
A: ASCII
3.4.4 Registering devices
To perform a simulation using the monitor all window, a device must be registered.
Three methods are available to register a device.
Selecting and registering a device on the ladder monitor window
File
➔
Monitor All
1. On the ladder monitor, select the device to be displayed.
• When a device is clicked, its color is changed to indicate that it is selected.
Contact status
Device No. Current value
Preset value
Comment
Cursor
Scroll bar
Display Bit Radix Sign
format
B1 1 2 Not provided
B16 16 2 Not provided
O16 16 8 Not provided
O32 32 8 Not provided
D16 16 10 Not provided
D32 32 10 Not provided
d16 16 10 Provided
d32 32 10 Provided
H16 16 16 Not provided
H32 32 16 Not provided
A16 16 ASC –
A32 32 ASC –
KVSKA Chap 03.P65 08.3.11, 11:29 AM113
Hi