Seitenansicht 71
4-18
4
Program
4-7 Settings for Limit Read Digits
The limit read digits function can be set to one of the following options.
Select the appropriate setting for the intended application.
z Limit all settings
This option reads the set number of digits for the barcode, no matter what type of code is
being read.
To set the number of digits, read three barcodes for the decimal program code ( page
4-26).
z Limit individual settings
This option sets the number of digits and code type to read for the block and reads only
the specified block.
Up to seven blocks can be specified.
When limiting multiple digits for the same type of code, set the limits by block.
When setting multiple blocks, the blocks must be set towards the beginning of the list
from block 1.
Set the number of digits to read by using the decimal program code ( page 4-26).
Set code type ( page 4-27) by using the decimal program code ( page 4-26).
Example 1: Read 10 digits for CODE39 and 14 digits for ITF
Block 1 settings
1. Read the "Block 1 — digit settings" barcode.
2. Read the decimal program codes "0," "1," and "0."
3. Read the "Block 1 — code type settings" barcode.
4. Read the decimal program codes "0," "8," and "0."
Block 2 settings
5. Read the "Block 2 — digit settings" barcode.
6. Read the decimal program codes "0," "1," and "4."
7. Read the "Block 2 — code type settings" barcode.
8. Read the decimal program codes "0," "8," and "2."