3-3 Cyclic communication
3-9
3
Communicating with FD-MH Series
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -
Monitor Data (84 Words (168 Bytes)) Assembly Instance (Instance ID): 64H
This is the device map for the monitor data to be assigned to the IN area.
For details on each parameter, refer to "Parameter List" (Page 3-11).
For details on current value 0 and current value 1, refer to "Current Value 0/
Current Value 1" (Page 3-12).
ID numbers (ID01 to ID10) are assigned for each sensor amplifier according to the
number of sensor amplifiers. The ID numbers larger than the number of connected
sensor amplifiers and ID11 to ID15 are not assigned.
Name
Address
(Byte)
bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
Status
0
Reserved for system
DL-EP1
Error Status
1 Error Status
Warning
Status
Reserved for system
Sensor
Error
Status
2 ID08 . . . . . ID01
3
Reserved for
system
ID15 . . . . . ID09
Sensor
Warning
Status
4 ID08 . . . . . ID01
5
Reserved for
system
ID15 . . . . . ID09
Current
Value 0
Over
Range
6 ID08 . . . . . ID01
7
Reserved for
system
ID15 . . . . . ID09
Current
Value 0
Under
Range
8 ID08 . . . . . ID01
9
Reserved for
system
ID15 . . . . . ID09
Current
Value 0
Invalid
10 ID08 . . . . . ID01
11
Reserved for
system
ID15 . . . . . ID09
Current
Value 1
Over
Range
12 ID08 . . . . . ID01
13
Reserved for
system
ID15 . . . . . ID09
Current
Value 1
Under
Range
14 ID08 . . . . . ID01
15
Reserved for
system
ID15 . . . . . ID09
Current
Value 1
Invalid
16 ID08 . . . . . ID01
17
Reserved for
system
ID15 . . . . . ID09
Output 1
18 ID08 . . . . . ID01
19
Reserved for
system
ID15 . . . . . ID09
Output 2
20 ID08 . . . . . ID01
21
Reserved for
system
ID15 . . . . . ID09
Output 3
22 ID08 . . . . . ID01
23
Reserved for
system
ID15 . . . . . ID09
Output 4
(Unassigned)
24 ID08 . . . . . ID01
25
Reserved for
system
ID15 . . . . . ID09
Kommentare zu diesen Handbüchern