3-3 Cyclic communication
3-15
3
Communicating with FD-MH Series
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -
Warning code list
No warning code occurs in the DL-EP1 and in the FD-MH Series sensor amplifiers
connected to the DL-EP1.
The data to the sensor amplifier is assigned to the OUT area of the EtherNet/IP
scanner.
External Input (5 Words (10 Bytes)) assembly instance (Instance ID): 65H
ID numbers (ID01 to ID10) are assigned for each sensor amplifier according to the
number of sensor amplifiers. The ID numbers larger than the number of connected
sensor amplifiers and ID11 to ID15 are not assigned.
Assignment to OUT Area (Scanner to DL-EP1)
DL-EP1 data
Scanner's OUT area
Address 0
Address 1
Address 9
External Input
(Assembly Instance: 101)
1-byte (8-bit) data
Name
Address
(Byte)
bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
External
Input
Request 1
(Integration
Reset)
0 ID08 . . . . . ID01
1
Reserved for
system
ID15 . . . . . ID09
External
Input
Request 2
(Flow HOLD
Reset)
2 ID08 . . . . . ID01
3
Reserved for
system
ID15 . . . . . ID09
External
Input
Request 3
(Unassigned)
4 ID08 . . . . . ID01
5
Reserved for
system
ID15 . . . . . ID09
External
Input
Request 4
(Temperature
HOLD Reset)
6 ID08 . . . . . ID01
7
Reserved for
system
ID15 . . . . . ID09
External
Input
Request 5
(Unassigned)
8 ID08 . . . . . ID01
9
Reserved for
system
ID15 . . . . . ID09