
Chapter 3 Use of Common Functions
3
40
3.2.5 Offset function [x]
The offset function allows any value to be added to or subtracted from the
displayed value. When an offset value is preset, activating the auto-zero function
displays the offset value.
Applications of the offset function
• The displayed value can be changed to a desired value by performing addition
or subtraction.
• The displayed value can be reset to the dimension of the master target that was
previously measured.
Setting function "x"
1. Press the for at least 2 seconds.
The sensor enters the common function selection mode.
2. Press the
key to make "x" flash.
3. Press the
or key to enter the offset setting state.
SET
CALL
HIGH TIM
GO
LOW
FUNC
UTILITY
MODE
CALIB
SET
CALL
HIGH TIM
GO
LOW
FUNC
UTILITY
MODE
CALIB
Add "0.003" to the
displayed value using the
offset function.
SET
CALL
HIGH TIM
GO
LOW
FUNC
UTILITY
MODE
CALIB
The master target
measures 10 mm.
Set the offset value to
"10.000" and then
activate the auto-zero
function.
Ok