Chapter 4 Use of Data Processing Functions
4
61
4.3.3 Measurement period [[]
This function sets/selects the sampling period to use the hold measurement.
Trigger level and trigger hysteresis
■ For internal trigger down operation
• By setting the trigger hysteresis, the chattering of the internal trigger signals can
be ignored.
Note: When the cyclical difference measurement function is selected, the trigger
hysteresis is used differently from the operation above.
➮
Refer to the timing
diagram on page 59 for details.
• The trigger level and trigger hysteresis are specified with numerical values.
Note 1: The trigger level can be set within the range of ±19.999.
Note 2: The trigger hysteresis can be set up to +19.999.
* The trigger hysteresis is factory-adjusted to 10 digits.
Sampling delay and sampling period
■ Sampling delay
Specify the time between the instant when the trigger signal turns ON and the
beginning of the sampling period.
noitcnuF
.oN
noitcnuFnoitpircseD
0-[
tupnilanretxE
ehtgnisuybdoirepgnilpmasehtseificepS
.stupniteser-dlohdnagnimit
1-[
pureggirtlanretnI
derusaemehtnehwslangisreggirtNOsnruT
.levelreggirtdeificepsasdeecxeeulav
2-[
nwodreggirtlanretnI
derusaemehtnehwslangisreggirtNOsnruT
.levelreggirtdeificepsawolebsllafeulav
(v)
0
(Time)
Internal timing
The chattering of trigger signals is ignored.
Trigger hysteresis
Trigger level
Ok