Keyence IV Series Bedienungsanleitung Seite 33

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 110
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 32
3-11
- IV Series Users Manual (Field Network) -
Data allocation in the cyclic communication
Address Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
54 - 55
Position correction score MAX (Unsigned 16-bit integer)
56 - 57
Position correction score MIN (Unsigned 16-bit integer)
58 - 59
Position correction score Lower threshold (Unsigned 16-bit integer)
60 - 71
Reserved by system
72 - 73
Tool 1 score (Unsigned 16-bit integer)
74 - 75
Tool 1 score MAX (Unsigned 16-bit integer)
76 - 77
Tool 1 score MIN (Unsigned 16-bit integer)
78 - 79
Tool 1 lower threshold (Unsigned 16-bit integer)
80 - 81
Tool 1 upper threshold (Unsigned 16-bit integer)
82 - 91
Reserved by system
92 - 391
Tool 2 to 16 (Same as Tool 1)
The start address of tool number “n” is 72 + (n-1) x 20
3
Cyclic communication
Seitenansicht 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 109 110

Kommentare zu diesen Handbüchern

Keine Kommentare