- IV Series Users Manual (Field Network) -
Data allocations in the data I/O communication
Status Modules (IV series → PLC)
Status Modules are modules that write responses from the IV series to the PLC.
The device map of the data allocated for the Status Modules is as shown below.
These parameters output the statuses, status results and statistics information of the IV series.
For details of each parameter, refer to “Status Modules parameter details” (Page 5-22).
Command Status Bits
Slot No.: 2
Module size: 4 bytes
Address Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
0 Reserved by system
Buffer
clear
response
Statistics
reset
response
Warning
clear
response
Program
switching
response
Master
registration
response
Trigger
response
1 Reserved by system
Program
switching
failed
Master
registration
failed
Trigger
failed
2 Reserved by system Ready RUN
Imaging
status
BUSY
Result
update
complete
Result
available
3 Error Warning
Buffer
overrun
Reserved by system
Device Result Bits
Slot No.: 3
Module size: 4 bytes
Address Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
0 Reserved by system LOGIC4 LOGIC3 LOGIC2 LOGIC1
Position
correction
Overall
judgment
1 Reserved by system
2 Tool 8 Tool 7 Tool 6 Tool 5 Tool 4 Tool 3 Tool 2 Tool 1
3 Tool 16 Tool 15 Tool 14 Tool 13 Tool 12 Tool 11 Tool 10 Tool 9
5
Data I/O communication