A-4
- IV Series User’s Manual (Field Network) -
Reference program (EtherNet/IP)
Handshake control [Enabled]
Keyence KV series
Line 1
Line 2
Line 3
Line 4
Line 5
REQ Trigger response Trigger request
Result acquisition
complete notication
MOV
Tool score DM2000
Result available
Trigger request
Result available
Result available
Result acquisition
complete notication
Description of the reference program
Line 1/Line 2
Sets “REQ” to ON and executes a trigger request.
“Trigger response” ON will set “Trigger request” to OFF (“Trigger request” is retained until “Trigger
response” is set to ON).
Line 3
The result available bit becomes ON to copy the data written in the tool score to DM2000.
Line 4/Line 5
“Result available” ON will execute a result acquisition completion notice.
“Result available” OFF will set “Result acquisition completion notice” to OFF (“Result acquisition completion
notice” will be retained until “Result available” becomes OFF).