Keyence IV Series Bedienungsanleitung Seite 98

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 110
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 97
A-4
- IV Series Users Manual (Field Network) -
Reference program (EtherNet/IP)
Handshake control [Enabled]
Keyence KV series
Line 1
Line 2
Line 3
Line 4
Line 5
REQ Trigger response Trigger request
Result acquisition
complete notication
MOV
Tool score DM2000
Result available
Trigger request
Result available
Result available
Result acquisition
complete notication
Description of the reference program
Line 1/Line 2
Sets “REQ” to ON and executes a trigger request.
“Trigger response” ON will set “Trigger request” to OFF (“Trigger request” is retained until “Trigger
response” is set to ON).
Line 3
The result available bit becomes ON to copy the data written in the tool score to DM2000.
Line 4/Line 5
“Result available” ON will execute a result acquisition completion notice.
“Result available” OFF will set “Result acquisition completion notice” to OFF (“Result acquisition completion
notice” will be retained until “Result available” becomes OFF).