- IV Series Users Manual (Field Network) -
Data I/O communication setting method
7
Set the IP address and subnet mask of the
CPU, and then click the [New] button.
The [Properties-New subnet Industrial Ethernet]
window will appear.
8
Click the [OK] button to return to the
[Properties-Ethernet interface PN-IO]
window.
9
Click the [OK] button.
10
Install the GSDML le if you are
conguring the IV series for the rst time.
Select [Options] - [Install GSD File] in the [HW
Cong] window.
Click the [Browse] button in the [Install GSD
File] window and specify the folder containing
the GSDML le.
Select the GSDML le for the IV series you
wish to install, and then click the [Install]
button.
The GSDML le for the IV series can be
downloaded from the KEYENCE web site.
http: //www.keyence.co.jp
5
Data I/O communication