6.1 Interrupt Instructions
KV-300
KV-10/80
3-274
6
Chapter 6 Interrupts, High-speed Counters, Positioning Control
INT / RETI
2008
1
EI
2203
2002
2002
CTH1
0005
END
INT
CTC2
RETI
2
4
0000
5
3
CTH1 #05000
CTC2
SET
2813
0501
0501
SET RES
SET
RES
ENDH
Initial setting
When the operation is started, EI instruction enables interrupts.
Special utility relays No. 2200 through 2215 are turned OFF. Turning OFF 2203
disables CTC2 from resetting the CTH1 current value to 0.
Turning OFF 2206 allows interrupt to be generated at the rising edge of INT0003.
The value of DM0000 is reset to "0".
Turning ON special utility relay 2813 changes the input time constant to 10 µs.
1.0-µs internal clock pulses are counted using CTH1.
INT instruction with 0003 as the operand allows interrupts to be executed.
When interrupt is generated for the first time, 2206 is OFF. Therefore, program in
rung (a) is executed. Then, KEEP turns 2206 ON.
When interrupt is generated for the second time, 2206 is ON. Therefore, program
in rung (b) is executed to calculate the following:
(TM30 at 2nd execution) - (TM30 at 1st execution) = pulse width (unit: 1.0 µs)
The result is stored in DM0000.
Example 3
Interrupt by CTC
Pulses input to 0005 are counted. 0501 is turned ON when the number of pulses
reaches 5,000.
Coding
Line No. Instruction Operand Line No. Instruction Operand
0000 LD 2008 0010 LD 2002
0001 EI 0011 CTH 1 0005
0002 CON 0012 LD 0000
0003 SET 2203 0013 RES 0501
0004 CON 0014 END
0005 RES CTH1 0015 INT CTC2
0006 CON 0016 LD 2002
0007 CTC 2 #05000 0017 SET 0501
0008 CON 0018 RETI
0009 SET 2813 0019 ENDH
KVNKA Chap 06.p65 08.3.11, 0:10 PM274