  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 39
3-12
IB-E
3
Basic Operations
3-5 Initial Reset (Initialize)
When initial reset is performed, all settings, excluding the calibration function, are
initialized. (When initial reset is performed, make sure to register the reference light again.
"3-4 Reference Light Registration (Gain Adjustment) and Adjust Function" (page 3-10)
The polarity of the judgment output and check output, and also the analog output setting,
can be changed with the same operation.
Main screen
1
While holding down the [MODE] button on the main
screen, press the [SET] button 5 times.
[reset] will be displayed on the main display.
While pressing the
[MODE] button,
press the [SET]
button 5 times.
2
Press the / button to select [yes] and press the
[MODE] button.
If [no] is selected, the settings of output polarity and analog
output can be changed without initial reset.
[MODE] button
3
Press the / button to select the output polarity
and press the [MODE] button.
[MODE] button
4
Press the / button to select the analog output
and press the [MODE] button.
"9. Analog Output Scaling" (page 4-27)
[MODE] button
5
After the initialization is complete, [end] blinks several
times on the sub display and the main screen is
restored.
Reference
When buttons other than the / and [MODE] buttons are pressed
during the initial reset procedure, the initial reset is canceled and the
screen in step 2 is restored.
When you attempt to initialize the unit while the key lock
function is set, the screen shown on the right appears
and the initialization fails.
Cancel the key lock before attempting to initialize the
unit.
"3-9 Key Lock Function" (page 3-23)

LASER
BANK
0
1
2
3
HI
GO
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT

HOLD CALC
CHECK
;GU
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
T'5'V
GO
HOLD CALC
CHECK
Performing the initial reset
PRP
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
QWV
GO
HOLD CALC
CHECK
Output polarity
Setting value Description
npn NPN output
pnp PNP output
QHH
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
#P.)
GO
HOLD CALC
CHECK
Analog output
Setting value Description
off Not using the analog output
0-5u Analog output range is from 0 to 5 V.
-5-5u Analog output range is ±5 V.
1-5u Analog output range is from 1 to 5 V.
aMpr Analog output range is from 4 to 20 mA.
'PF
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
T'5'V
GO
HOLD CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
.QE
GO
HOLD CALC
CHECK