4-2 Basic Settings and Advanced Settings
4-27
IB-E
4
Setting Various Functions
The analog output scaling for the judgment value (P.V.) is set.
If the setting not to output the analog output is set, this screen is skipped.
"3-1 Operation when the Power is Turned On for the First Time" (page 3-2)
"3-5 Initial Reset (Initialize)" (page 3-12)
Relation of voltage and analog output in default state (dEFLt)
• Analog output setting: Other than -5 to 5 V
• Analog output setting: -5 to 5 V
9. Analog Output Scaling
Analog output Description
Default
value
No scaling
(Default setting)
Scaling is not performed.
Free range
Scaling is performed. The analog output range can be
changed by specifying the upper limit and lower limit of
the judgment value (P.V.).
Example 1: Lower limit < Upper limit
(Analog output 1 to 5 V)
Example 2: Lower limit > Upper limit
(Analog output 1 to 5 V)
If Upper limit = Lower limit is set, the analog output is output as below.
Judgment value (P.V.)
≤
Upper limit: Analog output lower limit (1 V when 1 to 5 V)
Judgment value (P.V.) > Upper limit: Analog output upper limit (5 V when 1
to 5 V)
5
1
(V)
Judgment
value
(P.V.)
Lower limit Upper limit
Output
lower limit
Output
upper limit
Judgment
value
(P.V.)
Lower limit Upper limit
(V)
5
1
Output
lower limit
Output
upper limit
% mode Dimension mode
% mode Dimension mode
Model Upper limit Lower limit
IB-01
100.00
0.00
IB-05 0.00
IB-10 0.00
IB-30 0.00
Model Upper limit Lower limit
IB-01 1.000 0.000
IB-05 5.000 0.000
IB-10 10.000 0.000
IB-30 30.000 0.000
Model Upper limit Lower limit
IB-01
100.00 - 100.00
IB-05
IB-10
IB-30
Model Upper limit Lower limit
IB-01 1.000 - 1.000
IB-05 5.000 - 5.000
IB-10 10.000 - 10.000
IB-30 30.000 - 30.000