3-6 Setting the Tolerance Setting Value
3-14
3
Basic Operations
IB-E
This is the method to directly enter the tolerance setting value (HIGH setting value, LOW
setting value).
1
Press the / button several times on the main screen. Then display the
HIGH setting value on the sub display (lower level).
"Sub Display (Lower Level)" (page 3-4)
2
Press the / button to set the HIGH setting value.
"1. Measurement Mode" (page 4-8)
3
Press the button once and display the LOW setting value on the sub
display (lower level).
4
Press the / button to set the LOW setting value.
"1. Measurement Mode" (page 4-8)
After setting, press the / button to return the sub display to the original display
as necessary.
Manual Setting
Item Measurement mode Setting range Default value
HIGH setting
value
% mode -999.99 to 999.99
20.00
Dimension mode -99.999 to 99.999
2.000
Item Measurement mode Setting range Default value
LOW setting
value
% mode -999.99 to 999.99
10.00
Dimension mode -99.999 to 99.999
1.000
Reference
As soon as the HIGH setting value and the LOW setting value are
entered, the judgment and output start with the new setting value.
GO

LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT

HOLD CALC
CHECK
[HI]
ON
HIGH setting value
GO
HOLD CALC
CHECK

LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT

LOW setting value
[LO]
ON