I/O Terminal
7
Chapter
E LT-9001-IM
Timing Chart
7-10
Binary output
OUT1 and OUT2 are updated asynchronously depending on the number of measurement times for
averaging or the options specified in the measurement mode.
Output contents of either OUT1 or OUT2 can be selected for binary output by using "BIN SEL input".
You can check whether the current binary output is OUT1 or OUT2 by checking "BIN OUT output".
OUT STB output is always output in a OUT STB cycle (T1).
Synchronize the binary data with the OUT STB signal to import.
The OUT STB cycle (minimum input time) (T1) and update cycle (T5) vary according to the settings.
Refer to "Timing Details" (page 7-13) for details.