4 Input/Output Terminals
Sample hold (trigger 2)
The measurement value is determined after the sampling period (T4) has elapsed by using the tim-
ing input ON as a trigger.
The minimum input time (T1), input response time (T2), sampling period (T4), and program No.
change time (T7) vary depending on the settings.
The STROBE time (T3) can be changed.
Auto-zero is canceled when the ZERO input is turned on for two seconds or more.
If you turn on the RESET input or the ZERO input during the sampling period, the sampling stops
and the comparator standby state is established.
Refer to page 4-17.
Refer to page 3-43.
Comparator output
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Binary output
STROBE output
TIMING input
RESET/
ZERO input
P1 to P3 inputs
0.2ms
Min
MinT1
MinT1 MinT1
T1
MaxT2
Max
T2
MaxT7
MinT1
Min T1
period (T4)
Sampling
T3