Chapter 7 Pitch Mode
75
7
22
22
2 Limit Setup
The reference value, upper limit, and lower limit can be set separately for each of
the four scanning heads.
■ Setting Procedure
1. Select the LIMIT SETUP screen.
Press the [LIMIT SETUP] button.
2. Set tolerance limits.
Press the button corresponding to the output for which tolerance limits are to be
set.
Set tolerance limits using the numeric keys, and press [ENTER].
Press [ESCAPE] to complete the entry.
Press [CANCEL] to cancel the entry. The value returns to the previous value.
Note: When the measured value exceeds the tolerance range, the value is dis-
played in reverse. The differentiation result relative to the tolerance limits is output
from the display unit and the control I/O board (optional).
When the measured value exceeds the upper limit or falls below the lower limit, the
HI1 output is turned on.
In PITCH mode, the Upper-Lower Limit indicates the difference from the Reference
value. If a measured value of more than 1.1000 mm is to be checked and the
Reference value is set to 1.000 mm, the Upper Limit should be +0.1000. If 0.9000
mm is to be checked, the Lower Limit should be -0.1000 mm.
HEAD1 • • • HEAD4
LIMIT
SETUP
LASER ON LIMIT SETUP P. 1PITCH
DISPLAY
DATA
LIMIT
SETUP
PROGRAM OPTIONS
HEAD1
HEAD2
HEAD3
HEAD4
Select Head to set the limits.
LIMIT SETUPHEAD1LASER ON P. 1PITCH
87
5 64
2 31
0
9
ENTER
CANCEL
ESCAPE
+0.0100
1.0000
UPPER LIMIT:
REFERENCE:
LOWER LIMIT: -0.0100